- All CategoriesAll Categories
- Full CAD LibraryFull CAD Library
- S16118-3
915 MHz Microwave Generator, 100 kW
S16118-3915 MHz Microwave Generator, 100 kW
915 MHz Microwave Generator, 100 kW, for high-power industrial microwave applications.
Unit of Measure
Type |
N/A Generators |
Product # |
N/A S16118-3 |
Type |
N/A Microwave Generators |
Waveguide Size |
N/A WR975 (R9) |
Frequency |
N/A 915 MHz |
| Power1 | N/A 100 CW |
Material |
N/A Stainless Steel |
Minimum Coolant Flow Rate |
N/A 7GPM at 50F - 11GPM at 70F |
Interface |
N/A EIA-271 CPRF |
Weight |
N/A 3100 lb |
Intended Purpose |
N/A Integrated into System |
Input Voltage |
N/A 480 VAC / Delta |
Input Frequency |
N/A 60 Hz |
Maximum Power Draw @ Full Output |
N/A 150kVA / 185FLA |
Soft Starter Included |
N/A Yes |
HMI Included |
N/A No |
Processer |
N/A Allen Bradley Remote IO |
Control Panel Requirement |
N/A Yes |
| Cooling Interface (Supply)2 | N/A 3/4" NPT (F) |
Cooling Interface (Return) |
N/A 1" NPT (M) |
| Cooling Capacity Required3 | N/A 140000 Btu/hr |
Length A |
N/A 66 in |
Length B |
N/A 44 in |
Length 6 |
N/A 87 in |
- 1
- 30,000 V/cm Breakdown Voltage
- Unpressurized Waveguide
- 1:00:1 VSWR
- Average power is based upon unpressurized painted aluminum waveguide, internal surface finish of 63µm, under free convective cooling with an operating temperature that is 25ºC above ambient temperature. Cooling options should be considered if the waveguide will be operating at higher average power levels - please consult factory.
- 2 Available Add-ons May Change Cooling Interface
- 3 Additional cooling capacity required if reflected power exceeds 5kW