- All CategoriesAll Categories
- Full CAD LibraryFull CAD Library
- S16118-5
922 MHz Microwave Generator, 75 kW
S16118-5922 MHz Microwave Generator, 75 kW
922 MHz Microwave Generator, 75 kW, for high-power industrial microwave applications.
Unit of Measure
Type |
N/A Generators |
Product # |
N/A S16118-5 |
Type |
N/A Microwave Generators |
Waveguide Size |
N/A WR975 (R9) |
Frequency |
N/A 922 MHz |
| Power1 | N/A 75 CW |
Material |
N/A Stainless Steel |
Minimum Coolant Flow Rate |
N/A 7GPM at 50F - 11GPM at 70F |
Interface |
N/A EIA-271 CPRF |
Weight |
N/A 2900 lb |
Intended Purpose |
N/A Integrated into System |
Input Voltage |
N/A 480 VAC / Delta |
Input Frequency |
N/A 50 Hz |
Maximum Power Draw @ Full Output |
N/A 108kVA / 130FLA |
Soft Starter Included |
N/A No |
HMI Included |
N/A No |
Processer |
N/A Allen Bradley Remote IO |
Control Panel Requirement |
N/A Yes |
| Cooling Interface (Supply)2 | N/A 3/4" NPT (F) |
Cooling Interface (Return) |
N/A 1" NPT (M) |
| Cooling Capacity Required3 | N/A 105000 Btu/hr |
Length A |
N/A 58 in |
Length B |
N/A 44 in |
Length 6 |
N/A 87 in |
- 1
- 30,000 V/cm Breakdown Voltage
- Unpressurized Waveguide
- 1:00:1 VSWR
- Average power is based upon unpressurized painted aluminum waveguide, internal surface finish of 63µm, under free convective cooling with an operating temperature that is 25ºC above ambient temperature. Cooling options should be considered if the waveguide will be operating at higher average power levels - please consult factory.
- 2 Available Add-ons May Change Cooling Interface
- 3 Additional cooling capacity required if reflected power exceeds 5kW